Lucene search

K

Iec104 Firmware Security Vulnerabilities

cve
cve

CVE-2021-22772

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when...

9.8CVSS

9.4AI Score

0.003EPSS

2021-07-21 03:15 PM
20
4
cve
cve

CVE-2019-13944

A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET I...

5.3CVSS

4.9AI Score

0.002EPSS

2019-12-12 07:15 PM
33
cve
cve

CVE-2019-13943

A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET I...

6.1CVSS

5.5AI Score

0.001EPSS

2019-12-12 07:15 PM
39
cve
cve

CVE-2019-13942

A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET I...

7.5CVSS

7.5AI Score

0.001EPSS

2019-12-12 07:15 PM
31
cve
cve

CVE-2018-16563

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet...

5.9CVSS

5.5AI Score

0.001EPSS

2019-03-21 04:00 PM
35
cve
cve

CVE-2019-6528

PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions.....

8.8CVSS

8.8AI Score

0.001EPSS

2019-03-05 08:29 PM
31
cve
cve

CVE-2018-11451

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100...

7.5CVSS

7.2AI Score

0.002EPSS

2018-07-23 09:29 PM
38
cve
cve

CVE-2018-11452

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100...

7.5CVSS

7.2AI Score

0.002EPSS

2018-07-23 09:29 PM
41